IPX5 and IPX6 classify resistance to direct, pressurized water streams, distinguished by the nozzle size and flow rate used during testing

Second Characteristic Numeral 5 and 6: Pressurized Water Jet Tests

Degrees IPX5 and IPX6 define the enclosure’s capability to withstand forceful water jets, simulating conditions like hosing down. Both tests utilize a standard hose nozzle (Figure 6) and require spraying the enclosure from all practicable directions.

  • IPX5 (Protected against water jets): This test uses a nozzle with an internal diameter of 6.3 mm. The required delivery rate is 12.5 l/min ± 5%. The core of the stream should be approximately 40 mm in diameter at 2.5 m distance from the nozzle.
  • IPX6 (Protected against powerful water jets): This test utilizes a larger nozzle with an internal diameter of 12.5 mm. The delivery rate is significantly higher at 100 l/min ± 5%. The core of the stream should be approximately 120 mm in diameter at 2.5 m distance.

The water pressure is adjusted solely to achieve the specified delivery rate. For both levels, the nozzle must be positioned between 2.5 m and 3 m from the enclosure surface.

The duration of the test is determined by the surface area of the enclosure: 1 minute per square meter of enclosure surface area likely to be sprayed, with a minimum duration of 3 minutes. The acceptance criteria stipulate that water projected in jets shall not have harmful effects, meaning ingress must not interfere with safety, cause tracking, or reach parts not designed to operate wet.

Related Articles

IPX9 is a specialized degree, introduced by Amendment 2, classifying protection against highly stressful, short-range water jets used in rigorous cleaning environments

Second Characteristic Numeral 9: High Pressure, High Temperature Jet Test The degree of protection IPX9, introduced by Amendment 2, is specific to enclosures resisting high pressure and temperature water jets. Water projected from any direction under these extreme conditions must not have harmful effects. The test procedure involves a specialized fan jet nozzle (Figures 7,…

The first characteristic numeral (1-4) simultaneously classifies protection against human access using specific probes and against the physical ingress of similarly sized solid objects

The first characteristic numeral (1 through 4) always implies the satisfaction of two conditions simultaneously: protection of persons against access to hazardous parts, and protection of the equipment against the ingress of solid foreign objects. This dual role ensures both operational safety and physical integrity against external contamination. The definitions for protection against access rely…

The IEC 60529 standard establishes a unified classification system for enclosure protection against three primary hazards, applicable up to 72.5 kV

The standard IEC 60529 describes a system for classifying the degrees of protection provided by enclosures for electrical equipment. This system is generally suitable for most electrical equipment, provided the rated voltage does not exceed 72.5 kV. The fundamental objective of this standard is multi-faceted: to provide definitions for degrees of protection, establish designations for…

Optional Letters for Enhanced Access and Test Condition Specificity

Optional additional letters (A-D) specify enhanced human access protection, while supplementary letters (H, M, S, W) define critical testing conditions and intended application. The IP Code allows for the inclusion of two sets of optional letters that modify or add context to the core protection rating. Additional Letters (A, B, C, D): Protection against access…